You are in the PROTOKOL universeSold by TADAM, for professionals only
Check today what went unchecked yesterday.
On-site hygiene testing for vending machines and water dispensers. One slide, one simple step, a result you can see with the naked eye.
Cleaned. But really clean? How can you tell?
Screen, buttons, flap, coin mechanism: a machine is touched hundreds of times a day. To the eye, nothing separates a surface under control from one that needs another clean.
Sample
10 seconds per side.
Clean gloves. Label the tube before opening it. Press the first side flat on the surface, turn the slide over, repeat next to it. Never touch the agar. Sample before cleaning, to see the usual state of the machine.

Close and record
One slide, one point, one line on the record sheet.
The slide goes straight back into its labelled tube. Write the machine, the area and the date on the record sheet.
Incubate
The agar does the work for you.
Place the tubes in the incubator, at 30 °C ± 1 °C: up to 18 slides at a time in the PROTOKOL mini incubator. At 24 hours, count the coliforms through the tube, without opening it, then leave to incubate.
Observe
What was invisible takes shape.
The microorganisms picked up from the surface multiply. They form colonies you can see with the naked eye. At 48 hours, count the yeasts and moulds. Leave to incubate: total flora is counted at 72 hours.
See for yourself
From doubt to proof.
At 72 hours, count the total flora. Compare with the matrix and note the level: you know where to step up cleaning, and you can show it.
You know where hands go. Test there.
Ten points per machine: the surfaces users touch and the damp areas only the technician sees. Technical surfaces are sampled with the machine switched off, by a person authorised to open the equipment.
Vending machine

User side
Technical side
Water dispenser

User side
Technical side
A slide is read without a laboratory.
The matrix in the kit gives a level and what to do next. Five levels, from 0 to 4, with our recommended thresholds in colonies per side. Each customer can adjust them in their account. Record the level of the more heavily loaded side. Illustrations: the matrix in the kit is the reference.
0, very low
Area under control. Keep testing.
- Total flora, coliforms
- Fewer than 10
- Yeasts, moulds
- None
1, low
Test again on the next visit.
- Total flora, coliforms
- 10 to 24
- Yeasts, moulds
- 1 to 9
2, moderate
Step up cleaning, then test again.
- Total flora, coliforms
- 25 to 50
- Yeasts, moulds
- 10 to 20
3, high
Corrective action, then a new test.
- Total flora, coliforms
- 51 to 200
- Yeasts, moulds
- 21 to 50
4, very high
Prompt action, then a new test.
- Total flora, coliforms
- More than 200
- Yeasts, moulds
- More than 50
What you get
- A picture of the tested surface at the time of the test.
- A comparison of the same point, test after test.
- A written record for each machine.
What the test does not replace
- Analysis by an accredited laboratory.
- Identification of a specific germ.
- Detection of viruses, which do not grow on agar.
- Your cleaning plan and your hygiene obligations.
You clean every week. Now you can show it.
- To your customersA dated record sheet, point by point.
- To your teamsThe same areas and the same method on every round.
- To your managementA trend for each machine, to clean where it counts.

In the box: all you need to sample and read.
The starter pack contains what you need to sample, label and read your slides. To incubate them, you also need an incubator set to 30 °C.
- 40 agar slides, 2 boxes of 20
- Instructions for use
- Reading matrix
- Sampling logbook, with the tracking sheets
- Roll of labels
- Box of 100 gloves
- Pen
Incubator not included. Choose the PROTOKOL mini incubator or equivalent equipment.
Price shown after signing in.

To add to your order: an incubator that fits on a corner of the workbench.
Adjustable from 25 to 45 °C, to be set to 30 °C for our slides. Accuracy of ± 1 °C, up to 18 slides. Transparent door to follow the cultures without opening. 230 V power supply, indoor use.
Tips and advice
The 5 mistakes that skew a test
Touching the agar, leaving the tube open, reusing a slide.
See the 5 mistakesWhere to sample on a vending machine
Ten points, from the buttons to the dispensing nozzles.
See the points to sampleReading a slide with the matrix
From the level observed to the action to take.
See the matrixFrequently asked questions
How long does it take to get a result?
As recommended by the manufacturer: coliforms at 24 hours, yeasts and moulds at 48 hours, total flora at 72 hours.
Do I need a laboratory?
No. You sample on site, then incubate and read the slide in the workshop, through the tube. The test does not replace analysis by an accredited laboratory.
Do I need an incubator?
Yes, set to 30 °C ± 1 °C. The starter pack does not include one: choose the PROTOKOL mini incubator or equivalent equipment.
Can I test several surfaces with one slide?
No. One slide tests a single surface: a button, a nozzle, a handle. Allow one slide per point tested, up to ten on one machine.
Are the slides single-use?
Yes. Each slide is used only once.
What should I do with a slide after reading it?
It contains live microorganisms. Keep the tube closed and disinfect it before throwing it away, as explained in the instructions.
Where should I keep the kit?
Store the slides between 10 and 25 °C, away from light, in their box. No refrigerator, no vehicle in the sun.